| Cell chemistry | Also known as | Electrode | Rechargeable | Commercialized | Voltage | Energy density | Specific power | Cost† | Self-discharge rate | Shelf life | |||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Anode | Electrolyte | Cathode | Cutoff | Nominal | 100% SOC | by mass | by volume | ||||||||
| year | V | V | V | MJ/kg (Wh/kg) |
MJ/L (Wh/L) |
W/kg | Wh/$ ($/kWh) |
%/month | years | ||||||
| Lead–acid | SLA VRLA PbAc |
Lead | H2SO4 | Lead dioxide | Yes | 1881[1] | 1.75[2] | 2.1[2] | 2.23–2.32[2] | 0.11–0.18 (30–50)[3] |
0.22–0.27 (60–75)[2] |
80-200[3][4] | 5.15–13.24 (76–194)[2] |
3–20[2] | |
| Zinc–carbon | Carbon–zinc | Zinc | NH4Cl | Manganese (IV) oxide | No | 1898[5] | 0.75–0.9[5] | 1.5[5] | 0.13 (36)[5] |
0.33 (92)[5] |
10–27[5] | 2.35 (425)[5] |
0.32[5] | 3–5[6] | |
| Zinc–air | PR | KOH | Oxygen | No | 1932[7] | 0.9[7] | 1.45–1.65[7] | 1.59 (442)[7] |
6.02 (1,673)[7] |
100[7] | 2.06 (486)[7] |
0.17[7] | 3[7] | ||
| Mercury oxide–zinc | Mercuric oxide Mercury cell |
NaOH/ KOH | Mercuric oxide | No | 1942–[8] 1996[9] | 0.9[10] | 1.35[10] | 0.36–0.44 (99–123)[10] |
1.1–1.8 (300–500)[10] |
2[8] | |||||
| Alkaline | Zn/MnO 2 LR |
KOH | Manganese (IV) oxide | No | 1949[11] | 0.9[12] | 1.5[13] | 1.6[12] | 0.31–0.68 (85–190)[14] |
0.90–1.56 (250–434)[14] |
50[14] | 44.12 (23)[15] |
0.17[14] | 5–10[6] | |
| Rechargeable alkaline | RAM | KOH | Yes | 1992[16] | 0.9[17] | 1.57[17] | 1.6[17] | <1[16] | |||||||
| Silver-oxide | SR | NaOH/ KOH | Silver oxide | No | 1960[18] | 1.2[19] | 1.55[19] | 1.6[20] | 0.47 (130)[20] |
1.8 (500)[20] |
|||||
| Nickel–zinc | NiZn | KOH | Nickel oxide hydroxide | Yes | 2009[16] | 0.9[16] | 1.65[16] | 1.85[16] | 13[16] | ||||||
| Nickel–iron | NiFe | Iron | KOH | Yes | 1901[21] | 0.75[22] | 1.2[22] | 1.65[22] | 0.07–0.09 (19–25)[23] |
0.45 (125)[24] |
100 | 3.13–4.17 (240–319)[1] |
20–30 | 30–[25] 50[26][27] | |
| Nickel–cadmium | NiCd NiCad |
Cadmium | KOH | Yes | c. 1960[28] | 0.9–1.05[29] | 1.2[30] | 1.3[29] | 0.11 (30)[30] |
0.36 (100)[30] |
150–200[31] | 10[16] | |||
| Nickel–hydrogen | NiH 2 Ni-H 2 |
Hydrogen | KOH | Yes | 1975[32] | 1.0[33] | 1.55[31] | 0.16–0.23 (45–65)[31] |
0.22 (60)[34] |
150–200[31] | 5[34] | ||||
| Nickel–metal hydride | NiMH Ni-MH |
Metal hydride | KOH | Yes | 1990[1] | 0.9–1.05[29] | 1.2[13] | 1.3[29] | 0.36 (100)[13] |
1.44 (401)[35] |
250–1,000 | 2.5 (399)[1] |
30[36] | ||
| Low self-discharge nickel–metal hydride | LSD NiMH | Yes | 2005[37] | 0.9–1.05[29] | 1.2 | 1.3[29] | 0.34 (95)[38] |
1.27 (353)[39] |
250–1,000 | 0.42[36] | |||||
| Lithium–manganese dioxide | Lithium Li-MnO 2 CR Li-Mn |
Lithium | Manganese dioxide | No | 1976[40] | 2[41] | 3[13] | 0.54–1.19 (150–330)[42] |
1.1–2.6 (300–710) [42] |
250–400[42] | 1 | 5–10[42] | |||
| Lithium–carbon monofluoride | Li-(CF) x BR |
Carbon monofluoride | No | 1976[40] | 2[43] | 3[43] | 0.94–2.81 (260–780)[42] |
1.58–5.32 (440–1,478) [42] |
50–80[42] | 0.2–0.3[44] | 15[42] | ||||
| Lithium–iron disulfide | Li-FeS 2 FR |
Iron disulfide | No | 1989[45] | 0.9[45] | 1.5[45] | 1.8[45] | 1.07 (297)[45] |
2.1 (580)[46] |
10-20[46] | |||||
| Lithium–titanate | Li 4Ti 5O 12 LTO |
Lithium manganese oxide or Lithium nickel manganese cobalt oxide | Yes | 2008[47] | 1.6–1.8[48] | 2.3–2.4[48] | 2.8[48] | 0.22–0.40 (60–110) |
0.64 (177) |
3,000– 5,100[49] | 0.37 (2683)[49] |
2–5[49] | 10–20[49] | ||
| Lithium cobalt oxide | LiCoO 2 ICR LCO Li‑cobalt[50] |
Graphite‡ | LiPF6/ LiBF4/ LiClO4 | Lithium cobalt oxide | Yes | 1991[51] | 2.5[52] | 3.7[53] | 4.2[52] | 0.70 (195)[53] |
2.0 (560)[53] |
2.09 (479)[1] |
|||
| Lithium iron phosphate | LiFePO 4 IFR LFP Li‑phosphate[50] |
Lithium iron phosphate | Yes | 1996[54] | 2[52] | 3.2[53] | 3.65[52] | 0.32–0.62 (90–172)[53][55][56] |
1.43 (396)[53][56] |
200[57]–1,200[58] | 7.2 (139)[59] | 4.5 | 20 years[60] | ||
| Lithium manganese oxide | LiMn 2O 4 IMR LMO Li‑manganese[50] |
Lithium manganese oxide | Yes | 1999[1] | 2.5[61] | 3.9[53] | 4.2[61] | 0.54 (150)[53] |
1.5 (420)[53] |
2.09 (479)[1] |
|||||
| Lithium nickel cobalt aluminium oxides | LiNiCoAlO 2 NCA NCR Li‑aluminium[50] |
Lithium nickel cobalt aluminium oxide | Yes | 1999 | 3.0[62] | 3.6[53] | 4.3[62] | 0.79 (220)[53] |
2.2 (600)[53] |
||||||
| Lithium nickel manganese cobalt oxide | LiNi xMn yCo 1-x-yO 2 INR NMC[50] NCM[53] |
Lithium nickel manganese cobalt oxide | Yes | 2008[63] | 2.5[52] | 3.6[53] | 4.2[52] | 0.74 (205)[53] |
2.1 (580)[53] |
||||||
^† Cost in inflation-adjusted 2025 USD.
^‡ Typical. See Lithium-ion battery § Negative electrode for alternative electrode materials.
Table References
[2] [14] [5] [7] [49] [1] [3] [4] [6] [9] [8] [10] [11] [12] [15] [17] [18] [16] [19] [13] [20] [21] [22] [23] [24] [25] [26] [27] [28] [29] [31] [30] [32] [34] [33] [35] [36] [37] [38] [39] [40] [41] [42] [43] [44] [45] [46] [47] [48] [50] [51] [52] [55] [56] [57] [58] [59] [53] [60] [54] [61] [62] [63]
Rechargeable characteristics
This is a table of characteristics common to rechargeable batteries.
Cycle life can be significantly affected by factors such as the ambient temperature and charge/discharge rate.[64] For the purposes of this table, typical conditions are assumed.
| Cell chemistry | Round-trip efficiency | Cycle durability at varying depth of discharge (DoD) cycles | ||||
|---|---|---|---|---|---|---|
| % | 100% DoD | 70-90% DoD | 40-60% DoD | <40% DoD | ||
| Lead–acid | 50–92[2] | 50–100[65] | 150–250 @ 70% DoD[65] | 300–500 @ 50% DoD[65] | >800 @ 30% DoD[65] | |
| Rechargeable alkaline | 5–100[16] | |||||
| Nickel–zinc | 100 to 50% capacity[16] | |||||
| Nickel–iron | 65–80 | 5,000 | ||||
| Nickel–cadmium | 70–90 | 500[28] | ||||
| Nickel–hydrogen | 85 | 20,000[34] | ||||
| Nickel–metal hydride | 66 | 300–800[16] | ||||
| Low self-discharge nickel–metal hydride battery | 500–1,500[16] | |||||
| Lithium cobalt oxide | 90 | 500–1,000 | ||||
| Lithium–titanate | 85–90 | >13,000[66] | ≫20,000 @ 80% DoD[67] | >60,000 @ 60% DoD[68] |
||
| Lithium iron phosphate | 90 | ≥2,000 @ 80% DoD[69] | 3,500–>9,000 @ 50% DoD[69] | >10,000 @ 20% DoD[69] | ||
| Lithium manganese oxide | 90 | 300–700 | ||||
Table References
Thermal runaway
Under certain conditions, some battery chemistries are at risk of thermal runaway, leading to cell rupture or combustion. As thermal runaway is determined not only by cell chemistry but also cell size, cell design and charge, only the worst-case values are reflected here.[70]
| Cell chemistry | Overcharge | Overheat | ||
|---|---|---|---|---|
| Onset | Onset | Runaway | Peak | |
| SOC% | °C | °C | °C/min | |
| Lithium cobalt oxide | 150 | 165 | 190 | 440 |
| Lithium iron phosphate | 100 | 220 | 240 | 21 |
| Lithium manganese oxide | 110 | 210 | 240 | 100+ |
| Lithium nickel cobalt aluminium oxide | 125 | 140 | 195 | 260 |