Coronary perfusion pressure
From Wikipedia, the free encyclopedia

Coronary perfusion pressure (CPP) refers to the pressure gradient that drives coronary blood pressure. The heart's function is to perfuse blood to the body; however, the heart's own myocardium (heart muscle) must, itself, be supplied for its own muscle function. The heart is supplied by coronary vessels, and therefore CPP is the blood pressure within those vessels. If pressures are too low in the coronary vasculature, then the myocardium risks ischemia (restricted blood flow) with subsequent myocardial infarction or cardiogenic shock.
The coronary arteries originate off of the ascending aorta and continue onto the surface of the heart (the epicardium). When the heart contracts during systole, the contraction compresses the coronary arteries, which prevents perfusion. Therefore, it is only when the heart relaxes, during diastole, that the coronary vessels open up and allow for perfusion; thus CPP is highest during diastole, unlike most other arteries, which experience higher perfusion pressures under systole. CPP can be measured by calculating the difference between the aortic pressure and the left ventricular end diastolic pressure (LVEDP):
Coronary Perfusion Pressure (CPP) = Aortic Diastolic Pressure – Left Ventricular end-diastolic Pressure (LVEDP)
In the research setting, the absolute CPP can be measured using coronary and aortic pressure transducers; however, CPP is not regularly measured in human clinical practice. During cardiac surgery, when a patient is placed on cardiopulmonary bypass, and blood is passed through the coronary vessels in a retrograde direction, CPP can be approximated by using the measured right atrial pressure in place of LVEDP because the coronary sinus drains into the right atrium.
CPP is not the sole determinant of coronary blood flow (CBF). CBF is also determined mainly by metabolic autoregulation. Sympathetic regulation plays some role in coronary dilation and constriction, but less so than in other vascular systems. That is, when the ventricular myocardium is working, it extracts oxygen from the coronary blood and produces adenosine as a byproduct of ATP use. Hypoxia and adenosine both contribute to coronary vasodilation, which increase CBF. Both higher CPP and greater vasodilation will result in higher CBF.[1]