Thermoresponsive polymers can be used as stationary phase in liquid chromatography.[1] Here, the polarity of the stationary phase can be varied by temperature changes, altering the power of separation without changing the column or solvent composition. Thermally related benefits of gas chromatography can now be applied to classes of compounds that are restricted to liquid chromatography due to their thermolability. In place of solvent gradient elution, thermoresponsive polymers allow the use of temperature gradients under purely aqueous isocratic conditions.[2] The versatility of the system is controlled not only through changing temperature, but through the addition of modifying moieties that allow for a choice of enhanced hydrophobic interaction, or by introducing the prospect of electrostatic interaction.[3] These developments have already introduced major improvements to the fields of hydrophobic interaction chromatography, size exclusion chromatography, ion exchange chromatography, and affinity chromatography separations as well as pseudo-solid phase extractions ("pseudo" because of phase transitions).
Gel permeation chromatography
The research that appeared to spark an onslaught of modified applications was a gel permeation chromatography technique of fixing poly(isopropyl acrylate) (PIPA) strands to glass beads and separating a mixture of dextrans, which was developed by Gewehr et al.[4] They found that between the temperatures of 25–32 °C, the elution time of dextrans at different molecular weights exhibited a dependence on the temperature. Dextrans of the highest molecular weight eluted first since the PIPA chains exhibit hydrophilicity at temperatures below the LCST. As the temperature of the elution increased, when the chains behave in a more hydrophobic manner, the elution times increased for each of the analytes for the given range. The trend generally applies over the entire temperature range, but there is a flattening of the curve before 25 °C and after 32 °C (the approximate LCST for this experiment). It is important to note that above the LCST, the PIPA acts as a typical nonpolar stationary phase that would be used in reverse-phased chromatography. There are also instances of the elution times increasing below 15 °C, which most likely can be attributed to the lower temperatures’ effects on mass transfer playing a more significant role on retention than the stationary phase behavior. This study showed that the resolution could essentially be tuned by adjusting the operating temperature. The scope of this study was limited to isothermal conditions and attaching polymer chains to glass beads. The results, however, were satisfying enough to inspire other investigations and modifications to create a more versatile stationary phase for the advancement of chromatography.
Enhancing hydrophobic interaction
Okano’s group expanded on their success by using different modifiers to enhance hydrophobicity through the attachment of butyl methacrylate (BMA), a hydrophobic comonomer.[5] For simplification the resultant polymer has been labeled as IBc (isopropylacrylamide butyl methacrylate copolymer). The polymers were synthesized using radical telomerization with varying BMA content. Where pure PNIPAAm was unable to resolve hydrophobic steroids at any temperature, IBc-grafted silica stationary phases were able to resolve steroid peaks with increasingly retarded retention times in correlation to both increased BMA content and increased temperature. They went on to develop a method to separate phenylthiohydantoin(PTH)-amino acids using their IBc stationary phase with a stronger emphasis of implementing environmentally friendly conditions using a purely aqueous phase in HPLC.[6] Another group separated catechins using PNIPAAm.[7]
Modifying the LCST for improved experimental parameters
Since the separation of biological molecules such as proteins would be better served by isocratic elution with an aqueous solvent, resolution of HPLC analysis should be tweaked in the area of stationary phases to elute such analytes that may be sensitive to organic solvents. Kanazawa et al. recognized the possibility of changing the LCST parameter through the addition of different moieties.[8] Kanazawa’s group investigated the reversible changes of PNIPAAm once modifying it with a carboxyl end. It was suggested that the modification leads to faster changes in conformation due to the restrictions introduced by the carboxyl group. They attached the carboxyl-terminated PNIPAAm chains to (aminopropyl)silica and used it as packing material for HPLC analysis of steroids. The separation took place under isocratic conditions using pure water as the mobile phase, and controlled the temperature using a water bath. They were able to shift the LCST from 32 °C to 20 °C by making the solution 1M in NaCl concentration. Of the 5 steroids and benzene, only testosterone could be resolved from the other peaks below the LCST (5 °C, LCST=20 °C in 1M NaCl). Above the LCST (25 °C, LCST=20 °C in 1M NaCl), all of the peaks are well resolved, and there is an increasing trend of retention time versus temperature up to 50 °C.
Size exclusion chromatography
Prior to these studies, HPLC analyses were tuned by modifying the mobile and stationary phases only. Gradient elution for HPLC merely meant changing the ratio of solvents to improve column efficiency, and this requires the use of sophisticated solvent pumping mechanisms along with extra steps and precautions in the chromatographic analysis. Enlightened by the prospect of using temperature gradient elutions for HPLC analyses, Hosoya et al. sought to make surface modification of HPLC stationary phases more accessible. Their study utilizes graft-type copolymerization of PNIPAAm onto macroporous polymeric materials.[9] The in-situ preparation compared the use of cyclohexanol and toluene as porogens in the preparation of the modified polystyrene seeds. Reverse-phased size-exclusion chromatography (SEC) revealed pore size and pore size distribution of the particles and its dependence on temperature. Cyclohexanol acted as a successful porogen showing a dependent relationship of pore size to temperature. The use of toluene as a porogen gave results that were similar to unmodified macroporous particles. This indicates that PNIPAAm can be successfully grafted onto the surface and within the pores of macroporous materials. The application of this preparatory technique gives rise to tunable pore sizes. Temperature gradient elutions can be used to improve column efficiency through the changing of pore size in SEC. The mechanism of the change in pore size is simple, the pores are smaller under LCST due to the elongated chains of PNIPAAm within the pores, as temperature increases to and above LCST, the chains retract into a globular formation increasing the pore size.